                                                      Type:thermocouple (thermal resistance) for power station

                                                      Illustrate:It is specially designed for power station to measure temperature for 30KW, 60KW power-generating set and concerned equipments. It is used to directly measure the temperature of liquid, vapor, gas, and solid surface ranging from-200℃ to 800℃ during production process.

                                                      Thermocouple (Thermal Resistance) for Power Station
                                                       

                                                      Application
                                                      It is specially designed for power station to measure temperature for 30KW, 60KW power-generating set and concerned equipments. It is used to directly measure the temperature  of liquid, vapor, gas, and solid surface ranging from-200℃ to 800℃ during production process.
                                                      Operation Theory
                                                      Thermocouple electrodes are made of two different materials. Temperature difference between measuring end and reference end results in pyroelectric potential, then display meter indicates the corresponding temperature to the pyroelectic potential.
                                                      It is based on that temperature change of material results in change of its resistance. When resistance value changes, the working instrument will display relevant temperature value.
                                                       
                                                      Main Technical Parameters
                                                      Executive Standard
                                                      IEC584
                                                      GB/T16839-1997
                                                      JB/T8622-1997
                                                      JB/T8623-1997
                                                       
                                                      Measuring Range & Tolerance
                                                      Thermocouple
                                                       

                                                      Type Graduation Tolerance Class
                                                      I II
                                                      Tolerance Value Measuring Range °C Tolerance Value Measuring Range °C
                                                      WRN K ±1.5°C -40~+375 ±2.5 °C -40~+333
                                                      ±0.004ltl 375~1000 ±0.0075 ltl 333~1200
                                                      WRE E ±1.5°C -40~+375 ±2.5°C -40~+333
                                                      ±0.004 ltl 375~1000 ±0.0075 ltl 333~900
                                                       
                                                      Thermal Resistance
                                                       

                                                      Type  Graduation Measuring Range ℃ Accuracy  Tolerance
                                                      WZP Pt100 -200~+500 A
                                                      B
                                                      ±(0.15+0.002) ltl
                                                      ±(0.30+0.005) ltl
                                                      WZC Cu50  
                                                      Cu100
                                                      -50~+100 --- ±(0.30+0.005) ltl
                                                       Note: It is absolute temperature value actually tested with thermal sensor.
                                                       
                                                      Insulation Resistance at Normal Temperature
                                                       
                                                      The insulation resistance between electrode and protection tube of thermocouple shall be no less than 1000Ω.m under condition that environment temperature is 20±15℃,relative humidity is no more than 80%, and testing voltage is D.C.500±50V.
                                                       
                                                      The insulation resistance between electrode and protection tube of thermal resistance shall be no less than 100M Ωunder condition that environment temperature is 15~35℃,relative humidity is no more than 80%, and testing voltage is D.C.10~100V.