sales@gninstruments.com

                                                      Type:CX-PR-VPR130-RG paperless recorder

                                                      Illustrate:Equipped with standard USB interface, support USB1.1, USB2.0 disk, support FAT16/32, the historical data transmitting is simple.

                                                      CX-PR-VPR130-RG Paperless Recorder


                                                      Brief Introduction
                                                      1.Fully isolated universal input, multiple signals input, without modules replacement, and software configuration is accessible.
                                                      2.Use 32M large-capacity flash memory chip to store historical data, no data lost even power-off occurred.
                                                      3.Standard serial communication interface: RS-232 and RS-485, Modbus RTU protocol.
                                                      4.The clipboard copy and paste function can facilitate user parameter settings.
                                                      5.The bit mark and unit of a project can be configured.
                                                      6.Four groups of curves, free-form curves match, and the curve color can be customized.
                                                      7.Equipped with standard USB interface, support USB1.1, USB2.0 disk, support FAT16/32, the historical data transmitting is simple.
                                                      8.External micro-printer is supported to satisfy the requirement of field printing.
                                                       
                                                      Main Parameters

                                                      1.Numbers of channels

                                                      Maximally 16 channels are supported.
                                                      2.Input
                                                      DDZ-II standard signal 0~5V , 0~10mA
                                                      DDZ-III standard signal 1~5V , 4~20mA(Power distributable)
                                                      Low voltage 0~20mV, 0~100mV
                                                      Thermal Resistance Pt100, Cu50
                                                      Thermocouple B, E, J, K, S, T
                                                      Resistance signal 0~400Ω
                                                      Frequency PI(0~30kHz, High level: 8.5~30V, Low level: 0~4.5V)(Please specify in order if needed)
                                                      Digital input signal DI
                                                      Analog output signal AO
                                                      Isolation Impedance 20MΩ @ 500V
                                                      3.Output
                                                      Current 4~20mA, Load capacity 750Ω(Maximally)
                                                      Communication RJ-11 communication interface,RS232/485 Protocol,Baud rate: 9600, 19200, 38400, 57600 Optional
                                                      USB Interface Multiple flash disks supported
                                                      Alarm Maximum 6 relay contacts, contact load: 0.5A@125VAC/1A@30VDC
                                                      4.Accuracy
                                                      Real-time display ±0.2% F.S
                                                      Curve display ±0.5% F.S
                                                      Memory accuracy ±0.2% F.S.
                                                      Common-mode rejection ratio > 120 dB
                                                      Series mode rejection ratio > 50 dB
                                                      Note: thermocouple cold-error should be removed.
                                                      5.Record intervals 11 intervals from 1 to 240 sec.: 1/2/4/8/12/24/36/60/120/180/240sec
                                                      6.Record capacity 64/128/192/248MB (FLASH capacity is optional)
                                                      7.Screen 5.6-inch true color TFT LCD, high brightness, CCFL backlight, and clear picture
                                                      8.Power supply New Switching Power Supply,85~265VAC,45~65HZ
                                                      9 .Conservation conditions
                                                      Temperature -20 to 60 C, avoid sunlight
                                                      Humidity <85% RH (non-condensing)
                                                      12 .Working conditions
                                                      Temperature 0 to 45C
                                                      Humidity 10%~85% RH (non-condensing)

                                                      Last:CX-PR-ASR200 paperless recorder Next:Without the

                                                      Contact Us

                                                      Office Address: Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)

                                                      Phone:021-57635022

                                                      E-mail:info@gnflowmeter.com

                                                      E-mail:sales@gninstruments.com

                                                      關閉
                                                      亚洲VA成无码人在线观看天堂