                                                      Type: CX-PR-ASR100 color paperless recorder

                                                      Illustrate:This manual helps customers to realize the function, setting, connection methods and ways of disposal when you meet problem. We earnestly request you to read this manual carefully before using in order to avoid damaging instrument and injuring person.

                                                      CX-PR-ASR100 Color Paperless Recorder


                                                      Attention
                                                      1.There are many plastic parts in this instrument panel. Please do use dry soft cloth for cleaning.
                                                      2.Solvents are not allowed for cleaning.
                                                      3.Please keep the LCD screen away from any sharpen goods.
                                                      4.Please keep any mechanical impact away during the instrument working. It might cause internal component dam age or
                                                      5.system breaks down. Turn offthe power for any maintenance if necessary. P lease contact our customer service department or
                                                      6.local dealer ifany unusual sound, belches smoke or unusual smell was found.
                                                      7.Turn off the power when the instrument is maintained.
                                                      8.Not insert or pluck the lines of communication.
                                                       
                                                      Environment
                                                      1.To ensure the instruments be normal working, non-strong interference control panel is strongly recommended to be installed on.
                                                      2.The panel steel plate thickness should not be lower than 4mm.
                                                      3.The instruments operating ambient temperature: -15 - 60 , humidity: 10% - 85% (without condensation) is recommended.
                                                      4.Please keep away from the direct sunlight, the multi-steam, the multi-caustic gases and the source ofthe electromagnetism environment.

                                                      Main Parameters

                                                      Accuracy 0.5 %FS±1 digit  or  0.2%FS±1 digit
                                                      Small-signal removal 0 — 25.5%FS
                                                      Measuring range -9999 — 99999 digit
                                                      Sampling Period 0.25 second
                                                      InterrecordTime Between 1 second and 4 minutes take a second as a unit there are 240 ways for you to choose
                                                      Display mode High resolution, brightness adjustable, wide view angle and bright TFT color LCD (320x234)                     with saving screen (5.6” for ASR100 series)
                                                      Parameters setting ByKey nods or upper linking computer setting. Security lock function is available
                                                      Alarm 4alarmpointsperchannelareavailable.Upper/loweralarm, rate-of-change and differential limit; Alarm output delay, alarm  delay  high  to  low,  external connection  sound available, max 12 latest alarm  messages  are  saved  per channel.
                                                      Communication port RS-232,RS-485:Buadrate1200–115200bps
                                                      Printer       TPμP-A40 micro printer is recommended.
                                                       
                                                      Capacity(Mbit) Interrecord time (S) Channel  Number Approx recording date
                                                      32 (Default configuration)
                                                       
                                                      10 1 683
                                                      2 341
                                                      4 170
                                                      8 82
                                                      12 55
                                                      240 1 16401
                                                      2 8200
                                                      4 4100
                                                      8 1984
                                                      12 1322
                                                      64(Extened)
                                                       
                                                      10 1 1594
                                                      2 797
                                                      4 398
                                                      8 192
                                                      12 128
                                                      240 1 38037
                                                      2 19134
                                                      4 9567
                                                      8 4629
                                                      12 3086
                                                      128(Extend)
                                                       
                                                      10 1 3415
                                                      2 1705
                                                      4 850
                                                      8 410
                                                      16 275
                                                      240 1 82005
                                                      2 41000
                                                      4 20500
                                                      8 9920
                                                      12 6610

                                                      Last:Without the Next:CX-PR-ASR200 paperless recorder