sales@gninstruments.com

                                                      Type:CX-RCB precision conductivity/tds/salinity meter

                                                      Illustrate: CX-RCB Precision Conductivity/TDS/Salinity Meter Main Features 1.Microprocessor-based meter, high accuracy, good repetition 2.Self-diagnostic for easy trouble-shooting 3.Meter factory reset function: users can use this function to reset the meter..

                                                      CX-RCB Precision Conductivity/TDS/Salinity Meter

                                                      Main Features
                                                      1.Microprocessor-based meter, high accuracy, good repetition
                                                      2.Self-diagnostic for easy trouble-shooting
                                                      3.Meter factory reset function: users can use this function to reset the meter to the factory default and data log for convenient operation
                                                      4.Three set buffer selection–NIST, USA, DIN
                                                      5.1-3 points automatic push-button calibration
                                                      6.Electrode slope display for easy judgment of electrode performance
                                                      7.Selectable automatic/manual temperature compensation
                                                      8.Stability and average function for optimized results
                                                      9.Auto-sleep function for Benchtop meter
                                                      10.Auto-off conserves energy and lengthens battery lifespan (Portable Meter)
                                                      11.Low battery indicator: when battery icon lights up, battery power is low. Replace batteries with fresh ones as soon as possible.
                                                      12.Store and output data function: the meter can store up to 500 sets data. Data can be sent to computer via USB link.
                                                       
                                                      Configuration

                                                      Model Description Configuration Application Field
                                                      CX-RCB
                                                      6000-01
                                                      Precision Benchtop COND/TDS Meter Benchtop COND/TDS meter (RCB6000)
                                                      Swing arm electrode stand (H-200)
                                                      Glass conductivity electrode with ATC (0301W)
                                                      Measuring Cond / TDS for surface water, or regular simple water, not pure water
                                                      CX-RCB
                                                      6000-02
                                                      Precision Benchtop
                                                      COND/TDS
                                                      For Pure Water
                                                      Benchtop COND/TDS meter (RCB6000)
                                                      Swing arm electrode stand (H-200)
                                                      Glass conductivity electrode with ATC (0302W)
                                                      Measuring Cond / TDS for pure water, such as medical, electricity or chemical industries
                                                      CX-RCB
                                                      6000-03
                                                      Precision Benchtop
                                                      Salinity Meter
                                                      Benchtop Salinity meter (RCB6000)
                                                      Swing arm electrode stand (H-200)
                                                      Glass conductivity electrode (0303)
                                                      Stainless temperature electrode (T-10)
                                                      Measuring salinity for solution
                                                      CX-RCB
                                                      6000-10
                                                      Precision Benchtop
                                                      COND/TDS/Salinity
                                                      Meter
                                                      Benchtop COND/TDS/Salinity meter (RCB6000)
                                                      Swing arm electrode stand (H-200)
                                                      Glass conductivity electrode (0300)
                                                      Glass conductivity electrode (0303)
                                                      Stainless temperature electrode (T-10)
                                                      Measuring Cond / TDS / Salinity for surface water, or regular simple water, not pure water
                                                       
                                                      Main Parameters

                                                      Model CX-RCB6000/CX-RCB600
                                                      Cond Range 0-19.99μS/cm / 20.00-199.9μS/cm / 200.0-1999μS/cm / 2.00-19.99mS/cm / 20.00-199.9mS/cm
                                                      Cond Accuracy 1% FS
                                                      Cond Calibration Point 3 points
                                                      TDS Range 0.000-9.999mg/l / 10.00-99.99mg/l / 100.0-999.9mg/l / 1000-9999mg/l
                                                      Salinity Range 0.0-80.0ppt
                                                      Salinity Solution 0.1ppt
                                                      Temperature Range 0.0-99.9C / 32-212F
                                                      Temperature Solution 0.1C/0.1F
                                                      Temperature Accuracy +/-0.5C/+/-0.9F
                                                      Temperature Compensation 0.0-60.0 C Auto/Manual
                                                      Temperature Coefficient 0.0-3.0% 
                                                      Cell constant 0.1,1.0,10
                                                      Memory 500sets
                                                      Ambient Temperature 5-45C
                                                      Display Meter sleeps (Benchtop) or shuts off (Portable) automatically 15 minutes after last key is pressed
                                                      Input BNC,φ3.5mm sockets
                                                      Output USB
                                                      Power 9V DC adepter,500 mA 100/240V (Bench top)
                                                      4X1.5V“AAA”alkaline battery (Portable

                                                      Last:Without the Next:CX-RIB precision ph/ion meter

                                                      Contact Us

                                                      Office Address: Room 402, No. 650, Xinzhuan Rd., Jiuting Town, Songjiang District, Shanghai, China (Mainland)

                                                      Phone:021-57635022

                                                      E-mail:info@gnflowmeter.com