                                                      Location -> Products -> Flow -> Flowmeter For Liquid

                                                      Type:CX-WEMFM electromagnetic flow meter

                                                      Illustrate:1)DN6~DN2000 electromagnetic flow meter, 2)ISO,SGS,CE for exporting. 3) 9 consecutive years as gold supplier for export 4) More 80% electromagnetic flow meters for export

                                                         CX-WEMFM Electromagnetic Flow Meter
                                                       

                                                      Below is brief  Introduction and feature for our Electromagnetic flow meter

                                                      1.it can measure all kinds of  electronic conductivity liquid, such as corrosive liquid , mud and slurry ,water etc.

                                                      2.The result cannot be affected by temperature, pressure, viscosity and density.

                                                      3.Flow sensor and intelligent converter compact or separately composes a complete flowmeter.

                                                      Main features

                                                      1.No move assembly, no abrasion

                                                      2.Measuring range rate: 1:100

                                                      3.No flow enhance equipment

                                                      4.Suits for various of electronic conductivity liquid

                                                      5.No affect from temperature, viscosity, pressure and density

                                                      6.Anti-corrosion and  Self diagnose 

                                                      7.Measure both to and reverse flow

                                                      8.Huge display, easy operate

                                                      9.Long-term EEPROM to save data when lose power

                                                      10.Support MODBUS/HART communication protocol

                                                      11.Wide working volts range  or battery supply

                                                      12.Display chinese , english or  russian

                                                      13.It can be match with GPS

                                                      This photos is for various types for our electromagnetic flow meter

                                                       
                                                       Main Features
                                                      1.No move assembly, no abrasion
                                                      2.Measuring range rate: 1:100
                                                      3.No flow enhance equipment
                                                      4.Suits for various of electronic conductivity liquid
                                                      5.No affect from temperature, viscosity, pressure and density
                                                      6.Anti-corrosion
                                                      7.Measure both to and reverse flow
                                                      8.Huge display, easy operate
                                                      9.Long-term EEPROM to save data when lose power
                                                      10.Support MODBUS/HART communication protocol
                                                      11.Wide working volts range  or battery supply
                                                      12.Self diagnose

                                                      Below is our work shop for electromagnetic flow meter
                                                       




                                                      Technical Parameters

                                                      Display reaches 8 element liquid crystal display, current clock to indicate flow data. Units( m3 or L)
                                                      Structure inserted style, compact type or separate type
                                                      medium liquid or solid-liquid two phase fluid, conductivity >0.5μs/cm2
                                                      Range 0.05m/s~12m/s
                                                      Accuracy range between 0.1m/s~10m/s can be 0.5%
                                                      DN 6mm~2000 mm
                                                      PN PN6, PN10,PN16,PN25,PN40,PN63,PN100,PN160,PN250,PN420 optional
                                                      Output signal 4~20mA or frequency
                                                      Communication RS485,support MODBUS protocol (not standard)、support HART(option)
                                                      Connection DN6~DN2000  flange connection
                                                      Connection standard suits for all kinds of flange standard(eg:BS EN1092-1)
                                                      Standard accuracy apply to EN1434-1:2003 standard
                                                      Protection grade compact type for IP65,separately type for IP67or IP68(optional)
                                                      Power AC86~220V or DC24V(optional)
                                                      Ambient temperature 5~55C
                                                      Ambient humidity <85 % r.h (non condensation)
                                                                      
                                                      Electromagnetic Flow Sensor
                                                      Features
                                                      Sensor’s shell is sealed with carbon steel, only electrode and lining contact with medium.
                                                      Application area
                                                      conductivity fluid such as cold and warm water, pure water and corrosive material etc

                                                      Converter Technical Data

                                                      Current output 4~20Ma
                                                      Frequency output No resource pulse:
                                                      High level=external power supply-1V
                                                      External volts≤30 V
                                                      Low level≤0.5V
                                                      Load current≤50 mA
                                                      Max.frequency output :5KHz。
                                                      Frequency of pulse output: 0~5Hz。
                                                      Display With 8digit LCD display
                                                      Display unit Instantaneous flow units :m3 /h, m3 /m,m3 /s,L/h,L/m, L/s,G/h,G/m,G/s。Total flow units: m3,L,G。
                                                      Communication MODBUS protocol(optional)or HART(optional)
                                                      Protection grade IP65
                                                      Power supply 220 V AC +20/-60% ,50/60 Hz,24 V DC +50/-25% ,max.10VA
                                                      EMC radiation standard EN 61326-1:2006 (BS EN50081-1)
                                                      EMC anti-jimming standard EN 61326-1:2006 (BS EN50082-1)
                                                      CE security EN 61010-1:2001
                                                      Ambient temp. 5~55℃
                                                      Ambient humidity <85 % r.h. (non condensation)
                                                         
                                                      Remark:frequency output can set to forward flow(low level) or reverse flow(high level)
                                                       
                                                      Electrode Material

                                                      Material Symbol Anti-corrosion
                                                      SS316L V Suit for industrial water, domestic water, sewage water and other acid liquid etc.
                                                      Titanium Ti Suit for Sea water, chloride, hypochlorous
                                                      Hoag's alloyC Hc Bears the oxidized acid, like nitric acid, nitration mixture, chromic acid and sulfuric acid mixture. Also bears the oxidized salts or other oxidant environment corrosion. To the sea water, the alkaline solution, the oxide compound solution have the good inoxidizability. 
                                                      Hoag'salloy B Hb To the sulfuric acid, the phosphoric acid, the hydrofluoric acid and so on non-oxidized acid, the alkali salt have the good corrosion resistivity  。
                                                      Tantalum Ta Besides hydrofluoric acid, nearly ability all chemical mediator corrosion. Because its price is expensive, only uses in the hydrochloric acid and the strong sulfuric acid  。
                                                      tungsten carbide W Has the outstanding wear-resisting performance, uses in attrition medium specially and so on mud, paper pulp. 
                                                      Lining Material Selection
                                                      Lining material Anti-corrosion Working temp. Application area
                                                       (Ne) Bears the general low concentration acid and alkali salt the corrosion 0~70℃ Uses in the process water, the sewage, the low concentration acid and alkali salt brine. May reach most greatly according to the request 95℃.
                                                      DN50~DN2000 may choose the Ne lining material.
                                                       (FEP) Heat-resisting,the inoxidizability is good, the mechanical strength is high, the anti-attrition performance is good, cleans up when the surface is not easy to damage the inside lining.   
                                                      -20~180℃

                                                       
                                                      Besides the mortar and so on strong wearability medium's all fluids, may use in likely the tap water place hygienic request, may reach most greatly according to the request 180℃.
                                                      DN6~DN400 may choose the FEP lining material 
                                                      (PTFE) May resist all chemical mediator nearly the corrosion, the wearability is bad  -40~180℃ Cannot use in the negative pressure pipeline and the wearability strong fluid.
                                                      DN25~DN1000 may choose the PTFE lining material. 

                                                      This photos is for our calibration room for electromagnetic flow meter



                                                      Below photos is for installation samples for your reference.

                                                      This is our ISO,SGS,CE,national Patent certificates,measuring product certificates and business license


                                                      This is international marketing team ,
                                                      We work together like a 
                                                      BIG FAMILY and try our best to offer BEST SERVICE for our every clients!