                                                      Type:assembly thermal resistance

                                                      Illustrate:It is usually connected with display meter, recording meter and computer, etc. to directly measure temperature of liquid, vapor, gas and solid surface ranging from -200℃ to 500℃ during various production process.

                                                      Assembly thermal resistance

                                                       

                                                      Application
                                                      It is usually connected with display meter, recording meter and computer, etc. to directly measure temperature of liquid, vapor, gas and solid surface ranging from -200℃ to 500℃ during various production process.

                                                      Feature

                                                      Spring thermal sensor with good shock-proof performance
                                                      No compensational wire, spare cost.
                                                      High measuring accuracy
                                                      High mechanical strength, good pressure-resistant performance
                                                      imported film resistor with stable & reliable performance

                                                      Operation theory

                                                      It is based on that temperature change of material results in charge of its resistance.
                                                      When resistance value change, the working instrument will display relevant temperature.
                                                       
                                                      Main technical parameters

                                                      Executive standard
                                                      IEC751
                                                      IB/T8622-1997
                                                      JB/T8623-1997
                                                       
                                                      Insulation resistance at normal temperature

                                                      The insulation resistance between electrode and protection tube of armored resistance shall be no less than 100M Ω
                                                      under condition that environment temperature is 15~35 C, relative humidity is no more than 80%, and testing voltage is D.C.10~100V.
                                                       
                                                      Measuring range and tolerance
                                                      Model  Graduation Temperature range  Accuracy  Tolerances 
                                                      WZP  Pt100  -200-+500 Grade A  ± ( 0.15+0.002) ltl 
                                                      Grade B  ± ( 0.30+0.005) ltl 
                                                      WZC Cu50   Cu100  -50-+100  ---  ± ( 0.30+0.005) ltl 
                                                       
                                                        Remark: t is absolute value actually tested with thermal sensor.

                                                      Type naming method
                                                       

                                                      W Temperature instrument 
                                                        R themal resistance
                                                        Thermal element material 
                                                      p Pt
                                                      C Cu
                                                        Filament
                                                      Blank simplex
                                                      2 Duplex 
                                                        Mounting &fixing 
                                                      1 Without fixing device
                                                      2 Threaded connector
                                                      3 Movable flange
                                                      4 Fixed flange
                                                      5 Elbow tube connector
                                                      6 Threaded cone connection
                                                      7 Straight tube connector
                                                      8 Fixed threaded tube connector
                                                      9 Movable threaded tube connector
                                                        Junction box
                                                      2 Anti-spray type
                                                      3 Water-proof type
                                                        Protection tube diameter
                                                      0 Φ16 
                                                      1 Φ12
                                                        Measuring end
                                                      G  Variable cross section
                                                      W z p 2 2 3 1 G Model example



                                                      Type and specification
                                                       
                                                      Thermal element
                                                       

                                                      Name Type Graduation Measuring 
                                                      range ℃
                                                      specification
                                                      d L
                                                      Simplex Pt
                                                      thermal 
                                                      resistance
                                                      WZP-101 Pt100 -200~500 Φ3
                                                      Φ4
                                                      Φ5
                                                      Φ6
                                                      310
                                                      360
                                                      410
                                                      460
                                                      510
                                                      560
                                                      Duplex Pt
                                                      thermal
                                                      resistance
                                                      WZP2-101
                                                       
                                                      Wiring method
                                                       